Safety devices with position monitoring for combined operation of ventilation systems and non-room-sealed heating appliances
Stand-alone safety devices for monitoring the opening state of a window ensure that ventilation systems and non-room-sealed heating appliances can be operated safely in combined operation mode. If the defined minimum opening gap of the window is not adhered to, the safety device switches the ventilation unit off.
Regulatory framework
In this work area, DIBt grants national technical approvals (abZ) and/or general construction technique permits (aBG). European Technical Assessments (ETAs) can also be issued for corresponding products.
Please also note the applicable design and execution rules for ventilation technology, cf. in particular MVV TB, Parts A and B and the following information and technical rules.
National procedure
A national technical approval (abZ) and/or oder general construction technique permit (aBG) is granted upon application (see Model Building Code (MBO), Sections 16a(2) and18(2) and (4)). This also applies to amendments and supplements to, or renewals of existing approvals and/or construction technique permits.
No formal requirements apply. The following information is needed: name and address of the applicant, description of the product and/or construction technique and its field of use or application, type of decision required (new decision, amendment or supplement to, or renewal of, an existing decision).
Please feel free to use the template below.
- pdf-Datei Application for a national technical approval and/or construction technique permit (4 pages ) Version: 10 April 2024; Application form
- pdf-Datei Application for amendment / supplementation / renewal of a national technical approval and/or construction technique permit (4 pages ) Last updated: 10 April 2024; Application form
- pdf-Datei Guideline: How to provide drawings for national technical approvals and general construction technique permits (5 pages ) Version: July 2017
European Technical Assessment (ETA)
To start the ETA procedure, please submit the form below. We will then check if the prerequisites for issuing an ETA are met, i.e., in particular, if the product is not fully covered by an existing harmonised standard. If the prerequisites are met, we will check whether a European Assessment Document (EAD) covering the requested assessment scope already exists or still needs to be developed. If an EAD needs to be developed or amended, a complete technical file needs to be established before the procedure can begin.
- pdf-Datei Form for requesting a European Technical Assessment (ETA) (2 pages ) Last updated: 10 April 2024
Subject concerned | Applicant | Decision no. |
Validity
from / to |
---|---|---|---|
Funk-Fensterkontaktschalter FDS 200 - Sicherheitseinrichtung zur Gewährleistung eines gefahrlosen gemeinsamen Betriebes von Lüftungsanlagen und raumluftabhängigen Feuerstätten | Elektrotechnik Schabus GmbH & Co. KG Baierbacher Sraße 150 83071 Stephanskirchen | Z-85.2-10 |
Z:
10.01.2022 G: 10.01.2027 |
Funk-Abluftsteuerung FDS 100 - Sicherheitseinrichtung zur Gewährleistung eines gefahrlosen gemeinsamen Betriebes von Lüftungsanlagen und raumluftabhängigen Feuerstätten | Elektrotechnik Schabus GmbH & Co. KG Baierbacher Sraße 150 83071 Stephanskirchen | Z-85.2-11 |
Z:
25.01.2022 G: 25.01.2027 |
Kabel-Abluftsteuerungen vom Typ "KDS 110 und KDS 210" - Sicherheitseinrichtungen zur Gewährleistung eines gefahrlosen gemeinsamen Betriebes von Lüftungsanlagen und raumluftabhängigen Feuerstätten | Elektrotechnik Schabus GmbH & Co. KG Baierbacher Sraße 150 83071 Stephanskirchen | Z-85.2-14 |
Z:
24.01.2024 G: 19.06.2028 |
Baureihe Funk-Abluftsteuerung AS-7000 der Typen "AS-7020", "AS-7030" und "AS-7040" - Eigenständige Sicherheitseinrichtungen für den gemeinsamen gefahrlosen Betrieb von Lüftungsanlagen und raumluftabhängigen Feuerstätten | Protector GmbH An den Kolonaten 37 26160 Bad Zwischenahn | Z-85.2-19 |
Z:
22.08.2023 G: 22.08.2028 |
Sicherheitseinrichtung zur Gewährleistung eines gefahrlosen gemeinsamen Betriebes von Lüftungsanlagen und raumluftabhängigen Feuerstätten vom Typ Funk-Ablufsteuerung "AS-5120" | Protector GmbH An den Kolonaten 37 26160 Bad Zwischenahn | Z-85.2-21 |
Z:
10.10.2023 G: 10.10.2028 |
Funk-Abluft-Sicherheitsschalter "BL220F" und "BL220FI" als Sicherheitseinrichtungen zur Gewährleistung eines gefahrlosen gemeinsamen Betriebes von Lüftungsanlagen und raumluftabhängigen Feuerstätten | BROKO GmbH Max-Planck-Straße 13 85716 Unterschleißheim | Z-85.2-5 |
Z:
27.08.2024 G: 17.09.2029 |
Abluft-Sicherheitsschalter vom Typ "BL110K", "BL110Ki" und "BL110Ki 2.0" Sicherheitseinrichtung zur Gewährleistung eines gefahrlosen gemeinsamen Betriebes von Lüftungsanlagen und raumluftabhängigen Feuerstätten | BROKO GmbH Max-Planck-Straße 13 85716 Unterschleißheim | Z-85.2-6 |
Z:
14.02.2024 G: 22.04.2026 |